Home / Articles / O-ring groove design: depth, width and how to draw it
Draw + calculate

O-ring groove design: depth, width and how to draw it

7 min read · updated 18 Nov 2026

An O-ring groove (the gland) is designed from two rules: squeeze sets the groove depth, and gland fill sets the groove width. Too shallow and the ring is crushed and fails early; too deep or too narrow and it is never compressed, so it leaks. This guide gives the formulas built from the O-ring cross-section (CS), a worked example, and the exact steps to draw the groove cross-section in DXCAD2D Online.

The numbers you start from

An O-ring is specified mainly by its cross-section diameter (CS or W) — common values are 1.78, 2.62, 3.00 and 3.53 mm. The machined groove is a rectangle in cross-section, width G and depth D, while the ring has a round section. The cross-sectional area of the ring is

O-ring cross-section area: A = (π ÷ 4) × CS² — rubber deforms but keeps its volume, so when the ring is squeezed into the groove this area stays constant. That lets you compare it to the groove area to get the "gland fill" percentage.
width G depth D O-ring (round section Ø CS) squeezed into groove
O-ring groove cross-section: a rectangular groove width G, depth D; the round ring is squeezed flat by the mating face (dashed = ring before squeeze).

O-ring groove formulas (static seal)

For a static seal (flange, cover plate, end cap) use these two formulas.

Groove depth D: D = CS × (1 − squeeze%)
static squeeze is about 15–30% (commonly ~20%)

Groove width G: G = A ÷ (D × fill%) where A = (π ÷ 4)×CS²
gland fill is about 70–85% (leave room for swell and thermal expansion; design to ~75%)

Squeeze is the percentage the ring section is flattened — more squeeze seals harder but fatigues the rubber sooner. Gland fill is the fraction of the groove the rubber occupies; you must leave space for it to expand, or it will force the mating faces apart.

Worked example: a 3.0 mm cross-section O-ring

Design a groove for a CS = 3.00 mm O-ring, static seal, 20% squeeze, 75% gland fill.

StepCalculationResult
O-ring section area A0.7854 × 3.00²7.07 mm²
Groove depth D3.00 × (1 − 0.20)2.40 mm
Groove area needed7.07 ÷ 0.759.42 mm²
Groove width G9.42 ÷ 2.403.93 → use 3.9 mm

Check: groove 2.40 × 3.9 = 9.36 mm² → fill = 7.07 ÷ 9.36 = 75.5%, in the good range; squeeze = (3.00 − 2.40) ÷ 3.00 = 20%, on target. Final groove: 3.9 mm wide, 2.40 mm deep.

Extra details: break the groove-bottom corners with a small radius R 0.2–0.4 mm to stop the rubber tearing; keep the groove surface around Ra 0.8–1.6 µm; for a bore or shaft seal the ring is stretched or compressed on its diameter, so pick a size that stretches no more than ~5%.

Try it right now — a free 2D CAD in your browser. Nothing to install, no sign-up.

Open DXCAD2D Online

Drawing the groove cross-section in DXCAD2D

Draw half the groove in section to the worked numbers (3.9 wide, 2.40 deep).

  1. Draw the metal face edge with L (line) — a horizontal top surface line.
  2. Cut the groove with REC (rect): click the top-left corner of the groove, then type the relative size @3.9,-2.4 Enter — a 3.9 wide, 2.40 deep pocket.
  3. Round the groove-bottom corners with F (fillet), set radius 0.3, then click the two sides of each lower corner.
  4. Place the O-ring with C (circle) radius 1.5 (Ø 3.0), straddling the groove mouth to show the squeeze.
  5. Check sizes with ME (measure): click two points and read the width/depth before committing them.
  6. Add dimensions with DLI (dimension linear) on both width and depth.

If the groove repeats at several positions, use CO (copy) or AR (array) to duplicate the section along the pitch you need.

Frequently asked questions

how deep should an o-ring groove be

Groove depth = O-ring cross-section × (1 − squeeze). For a static seal use about 20% squeeze, so a 3.0 mm section needs a 3.0 × 0.8 = 2.4 mm deep groove.

how to calculate o-ring groove width

Aim for about 75% gland fill: width = O-ring section area ÷ (groove depth × 0.75). A 3.0 mm section gives roughly 3.9 mm width, leaving room for the rubber to expand.

how much squeeze on a static o-ring

About 15–30%, commonly ~20%. Dynamic (moving) seals use less, around 10–20%, to cut friction and wear.

why is the groove wider than the o-ring section

To leave space for the rubber to expand from heat and swell in oil. Filling the groove 100% would push the faces apart or extrude the ring, so design for about 70–85% fill.

Summary

An O-ring groove is controlled by two numbers: depth from squeeze (D = CS × (1 − squeeze), static ~20%) and width from gland fill (G = ring area ÷ (D × fill), fill ~75%). For a CS 3.0 mm ring that gives a groove 3.9 mm wide and 2.40 mm deep. Draw the section with REC in relative size, round the bottom corners with F, and dimension with DLI — always verify with ME before the part goes to the machine shop.